ISO 16889:2022
Beta Ratio ⇄ Filtration Efficiency Calculator
Bidirectional conversion between ISO 16889 Beta ratio (β_x(c)) and single-pass filtration efficiency (E_x(c)). Enter either a Beta ratio or an efficiency percentage; the calculator returns the inverse quantity and downstream particle concentration.
FORMULA
VARIABLES
ASSUMPTIONS
· Beta ratio is measured under steady-state flow conditions using ISO Fine Test Dust (ISO 12103-1 A2).
· Upstream and downstream counts are measured simultaneously by calibrated APCs per ISO 11171.
· The ratio is single-pass efficiency — multi-pass or steady-state cleanliness requires separate analysis.
LIMITATIONS
· Beta ratio is test-condition specific: values change with flow rate, pressure, and test dust type.
· Beta ratio does not account for filter bypass flow or unfiltered leakage paths.
· Efficiency at one particle size does not predict efficiency at other particle sizes.
· Very high Beta values (β > 1000) are difficult to measure accurately — APC downstream count approaches the detection limit.
CALCULATOR
RELATED TECHNOLOGIES
NANOFORCE™
SYNTRAX™
MACROCORE™
VALIDATION: ISO 16889:2022 Annex A — reference data from certified multipass test reports (Pall Corporation FP2B-A, Parker Hannifin ISO-16889 certification series). · SOURCE: ISO 16889:2022 · STATUS: VALIDATED